Mfg Part Number: B150BT13JX
NSN : 5950-01-208-5121
NIIN : 012085121
CAGE Code : 30882
Manufacturer: Micron Industries Corporation
Item Name : Transformer Power
Here at Internet For Aviation, we have B150BT13JX Transformer Power from Micron Industries Corporation, as well as a variety of other parts from reliable manufacturers. As the only independent distributor with a No China Sourcing policy, we go to great lengths to ensure that we source responsibly when it comes to certified standard items. If you’re in need of a specific B150BT13JX to aid you in your aircraft repair capabilities, simply search by NSN part number, NSN or Cage Code on our parts directory. Submit an instant RFQ and a representative will get back to you in as little as 15 minutes.
Note : We Will Not Share Your Information To Any Third Parties.
We pride ourselves in our abilities to deliver quality superior grade aviation parts in a timely schedule. Thanks to the various supply chain locations that we have across the United States. We can execute fast shipping times that outpace our competitors. Unlike other competitors, we can promise same day shipping and delivery right to the very place you need. We’re leaders in our industry thanks to our parts streamlining process which includes quick stock and acquisition of the certified product and fast shipping. For whatever needs you have, be they Transformer Power and B150BT13JX parts, we can procure and deliver in a schedule that fits with you! Contact us today for an immediate quote!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-208-5121 Item Description: Transformer Power | 5950 | 012085121 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
B150BT13JX | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.844 INCHES MINIMUM AND 2.906 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.094 INCHES MINIMUM AND 3.156 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.172 INCHES MINIMUM AND 0.234 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 150.0 VOLT-AMPERE SINGLE COMPONENT |
ADAT | BODY WIDTH | 3.719 INCHES MINIMUM AND 3.781 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.157 INCHES MINIMUM AND 3.219 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.3 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC VOLTS MINIMUM AND 120.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 1 TERMINAL BLOCK W/SCREWS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.969 INCHES MINIMUM AND 4.031 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CRMJ | WINDING POWER RATING | 75.0 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY |