Mfg Part Number: 9T58B3363G9
NSN : 5950-01-294-1275
NIIN : 012941275
CAGE Code : 03512
Manufacturer: General Electric Co
Item Name : Transformer Power
Here at Internet For Aviation, we have 9T58B3363G9 Transformer Power from General Electric Co, as well as a variety of other parts from reliable manufacturers. As the only independent distributor with a No China Sourcing policy, we go to great lengths to ensure that we source responsibly when it comes to certified standard items. If you’re in need of a specific 9T58B3363G9 to aid you in your aircraft repair capabilities, simply search by NSN part number, NSN or Cage Code on our parts directory. Submit an instant RFQ and a representative will get back to you in as little as 15 minutes.
Note : We Will Not Share Your Information To Any Third Parties.
We pride ourselves in our abilities to deliver quality superior grade aviation parts in a timely schedule. Thanks to the various supply chain locations that we have across the United States. We can execute fast shipping times that outpace our competitors. Unlike other competitors, we can promise same day shipping and delivery right to the very place you need. We’re leaders in our industry thanks to our parts streamlining process which includes quick stock and acquisition of the certified product and fast shipping. For whatever needs you have, be they Transformer Power and 9T58B3363G9 parts, we can procure and deliver in a schedule that fits with you! Contact us today for an immediate quote!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-294-1275 Item Description: Transformer Power | 5950 | 012941275 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9T58B3363G9 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 7.620 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 5.250 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 750.0 VOLT-AMPERE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 6.25 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
FEAT | SPECIAL FEATURES | NO JUMPERS SUPPLIED; TYPE K FUSE CLIPS MOUNTED ON SECONDARY |
ZZZK | SPECIFICATION/STANDARD DATA | 59678-11024280 MANUFACTURERS SPECIFICATION CONTROL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 4.750 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TERMINAL BLOCK W/SCREWS |
Semiconductor's Certifications and Memberships
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You'll Choose Buy Aviation Parts as Your Quick and Convenient Parts Distributor In the Future.
Request for Quote